site stats

Rc 16 in jcl

WebThe interpreter is so tight that I was unable to use JCL SET symbolics with IF/THEN/ENDIF statements, ... (PRCSTEP2.RUN AND PRCSTEP2.RC LT 16)' //STEP0002 EXEC PROC1 //STEP0003 EXEC PROC1 Oh well - another strike against JCL coding optimization attempts, while having somewhat similar angst ... WebFor unsuccessful completion with NOABEND in effect, DFSORT passes back a return code of 16, 20 or 28 to the operating system or the invoking program. For unsuccessful …

Flushed step return code in jcl - Stack Overflow

WebMar 17, 2016 · Control-M/JCL Verify incorrectly handles the SORT utility MODS statement. As result verification completes with. return code 16. Cause. Solution. Apply PTFs for BMC APAR BJ10327. For 8.0: PTFs PF03739 and PF03738. These PTFs are part of maintenance 8.0.04. For 9.0: PTFs PG02109 and PG02108. WebA core value of Ansible is that it is the glue that can work with just about everything. Integrate with what you have or build new playbooks with certified, open source content to create something new. Use your existing JCL, REXX, and z/OSMF assets or anything else using Ansible as the driver to automate IBM Z, z/OS and z/OS-based software. hillkellydodge.com https://artisanflare.com

Reason Codes - IBM

WebTerry Heinz. #4 / 12. JCL Return Code (RC) (R)eturn (C)ode is one of the ways a program can communicate with JCL. Job. steps can be executed/bypassed based on the RC of previous steps. Communication in the opposite direction (from JCL to program) can be done. via the PARM option of the execute statement. Web209 rows · Programmer Response: Change the JCL to reflect a disposition other than SHR … http://computer-programming-forum.com/48-cobol/e2a62d2095524b64.htm hilllo

COBOL input file to output file MAXCC(Error return code)=0012

Category:DFSORT return codes - IBM

Tags:Rc 16 in jcl

Rc 16 in jcl

Re: Question if COND code / IF THEN struct

Web再始動する場合に異なる jcl を必要とするバッチ・ジョブがある場合には、ポリシーを使用して、この情報を指すようにしてください。 再始動されている場合に別の jcl を指す自 … WebMar 17, 2016 · Control-M/JCL Verify incorrectly handles the SORT utility MODS statement. As result verification completes with. return code 16. Cause. Solution. Apply PTFs for …

Rc 16 in jcl

Did you know?

WebOct 28, 2009 · The RC of STEP01 is FLUSH. In the following condition://IF STEP01.RC = 0 THEN//://:How this condition will be executed ... by mathew28 » Fri Mar 16, 2012 2:39 pm ... Fri Mar 16, 2012 6:13 pm Flush all steps of a JCL based on return code from one step by ashokkumar_rn » Thu Apr 25, 2013 9:39 am 5 Replies 4637 Views Last ... WebJan 4, 2024 · Continuing a relational expression: You can continue relational expressions on the next JCL statement.Break the relational expression where a blank is valid on the current statement, and continue the expression beginning in columns 4 …

WebJul 7, 2005 · JCL & VSAM: Hi Guys, Here is my query, ll try to elaborate to the max details: ... Sat Jul 09, 2005 1:16 pm: Hi Guys, Thanks for your inputs SuperK, MGIndalco and Priyesh. … WebMar 3, 2024 · 3. I agree with what Bruce and cschneid have been stating. You can not invoke an ISPF service from a COBOL pgm using JCL unless the JCL is running ISPF in batch mode as in the example provided by cschneid. Without the ISPF environment ISPLINK will set rc=20 because it can not find an ISPF environment.

Web重大エラー (rc=16) 呼び出し側プログラムが、無効なパラメーターを指定してサービスを起動したか、 または、無効なモードで起動しました。 リカバリー不能エラー (rc=20) rmf … WebMay 24, 2011 · JES, JES2, JCL utilities, IDCAMS, Compile & Run JCLs, PROCs etc... Previous topic • Next topic • 8 posts • Page 1 of 1. Differece between MAXCC=8 and MAXCC=12. ... Please give me the difference between MAXCC= 8 or 12 or 16. Knowledge is wealth. coollearner Posts: 33 Joined: Thu Jun 03, 2010 9:45 am Has thanked: 0 time

WebMay 10, 2007 · Quote: Find a field value within a constant. For example, you can search the character constant C'J69,L92,J82' for the value in a 3-byte field. If the field value is C'J69', …

WebSep 29, 2008 · If the STEP1 RC is 16, then we have to execute STEP2 and STEP3. I have used the following COND in my STEP2. STEP2 EXEC DPBOPSSD,COND= (0,GT) (if the … smart final logoWebAug 9, 2024 · So your COND=(16,GT) means "If 16 is greater than the return code from any previous steps, don't execute this step". So this step would only execute if ALL the … smart final cakesWebOct 28, 2009 · The RC of STEP01 is FLUSH. In the following condition://IF STEP01.RC = 0 THEN//://:How this condition will be executed ... by mathew28 » Fri Mar 16, 2012 2:39 pm … hillleather.comWebIf a User, System, or RTS abend occurs in a job step, MFBSIJCL returns the decimal value of the user, system, or RTS status code by default. If this value is greater than 199, MFBSIJCL returns a final return code of 16 to the scheduler. Otherwise, the return code corresponds to the status code; for example, a user abend with return code 12 returns code 12. hilllock翻译WebMar 16, 2012 · by mathew28 » Fri Mar 16, 2012 2:39 pm . Hi, My JCL has the below steps. STEP01 ... STEP04, COND=(4,LE,STEP03) I want a step to execute, only if the previous step's RC = 0 or 4. But in the above case, when step 02 is skipped because step01's RC was 8. since, RC of Step02 was FLUSH. The step03 and step04 got executed. hillkoff coffeeWeb20 rows · If you specify EMPTYOK as an option, this return code is changed to RC 0. ISRSUPC continues to print any messages that relate to RC 28. 32: ERROR. Insufficient … hillkit warriorsWebMay 17, 2024 · 0. The input file and output file is declared as Fixed and is of length 80. But both input and output variables are of length less than 80. They have length of 27.So in player-details and output details add filler variable with length 80 - 27 = 53. Also make sure the input and output file length are 80. Share. hillkoff chang puek